RV generator repair in Phoenix
In summer the generator runs the AC when there's no hookup; in winter it often sits. Both are hard on it. Most onboard generators are Cummins Onan, and most problems come down to fuel, oil or a generator that wasn't run.
The tech drives out to wherever the RV sits — at home, in storage or at an RV resort.

Smell propane? Get everyone out of the RV, shut the tank valve if you can do it safely, and call 911 once you're well away from it.
Common problems
- Cranks but won't start
No fuel at the generator, stale fuel varnishing the carburetor, or a low-oil shutdown.
- Starts, then dies
Low oil level, a clogged fuel filter, a dirty air filter, or a fault the controller is flagging.
- Surges or hunts
Carburetor problems on gas units are common after a long sit.
- Runs but no power inside
The generator breaker on the unit, the transfer switch or the RV's main breaker.
Quick checks
- Fuel levelOn motorhomes the generator draws from the main fuel tank through a pickup set higher than the engine's, so it stops when the tank gets low — around a quarter tank on many coaches. Fill up and try again.
- OilCheck the dipstick with the generator level. Low oil shuts most units down by design.
- Fault codeOnan control switches blink a code after a shutdown. Count the blinks and look the code up in your owner's manual — Cummins posts the manuals online.
- BreakersCheck the breaker on the generator itself and the RV's main breaker.
- Start batteryOn many coaches the generator cranks off the house or chassis battery. Slow cranking or just a click points to a weak battery or a loose cable.
- Air filterValley dust clogs it. In dusty places check it more often than the regular interval in the manual.
Run it every month
Cummins Onan owner's manuals say to run a generator that isn't used often for at least two hours every month, at about half its rated load. That dries out moisture, keeps seals lubricated and burns off stale fuel. Running it with nothing turned on doesn't do the job — switch on the AC.
Many winter visitors leave their RV parked here through the summer. A generator that sat through the Phoenix heat is a common call when they come back.

What the technician does
They read the fault history, check fuel delivery and oil, clean or replace the carburetor on gas units, change filters and spark plugs, and test output voltage and frequency under load. They also check the transfer switch that picks between shore power and the generator.
Propane work — gas lines, the regulator, valves and burners — is a job for a technician trained on RV propane systems. Ask about their training before the work starts.
What it costs
| Job | Usual cost | Where the number comes from |
|---|---|---|
| Generator diagnosis, before parts and labor | $137–450 | Camping World, “Mobile RV Repair Cost Guide”, July 2026 |
| Technician's hourly rate | $140–200 | Micro-Air, “How much does it cost to replace an RV AC unit”, June 2026; Camping World, “RV Furnace Repair Cost Guide”, October 2026 |
Ballpark for 2026, not a quote. The technician sets the actual price after looking at your RV.
A carburetor cleaning or replacement on a gas unit is one of the more common bills after a long storage.
Numbers last checked November 2026.
Owners also ask
How do I reset my Onan generator?
Most Onan units have no reset button. Fix the cause the fault code points to — usually fuel or oil — then hold the start switch again. Check the breaker on the generator if it runs but nothing gets power.
How often should I change the oil?
Follow the interval in your manual. It's set in hours of running, with a once-a-year minimum on many models. An hour meter on the control panel tells you where you are.
Can a mobile tech work on my generator at a resort?
Most generator work is done on site through the access door. Some resorts limit running engines at certain hours — check with the office.
Get a mobile tech
Only your phone number is needed. Whichever tech picks up the job phones you.